PRODUCTS CENTER
Laos 12kV drop fuse
Category:
Product Description
![]() |
![]() |
![]() |
![]() |
|
SSOC1-12 drop fuse |
SSOC5-12 drop fuse | SSOC3-12 drop fuse (load type) | SSOC7-12 drop fuse (load type) |
-
According to standards and scope of application
|
The design and test of SSOC □ single column series outdoor high voltage AC drop fuse meet the requirements of the following standards: |
|
|
GB 311.1-2012 |
Insulation coordination-Part 1: Definitions, principles and rules |
|
GB/T 11022-2011 |
Common technical requirements for high-voltage switchgear and controlgear standards |
|
GB/T 15166.3-2008 |
High-voltage a.c. fuses-Part 3: Jet fuses |
|
DL/T 593-2006 |
Common technical requirements for high-voltage switchgear and controlgear standards |
|
DL/T 640-1997 |
Technical conditions for ordering outdoor AC high-voltage drop-out fuses and fuse elements |
SSOC□ single-column series drop fuse is the most commonly used short-circuit protection switch for branch lines and distribution transformers of 12kV distribution lines. It has the characteristics of economy, convenient operation and strong adaptability to outdoor environment. It is widely used in the primary side of 12kV distribution lines and distribution transformers for protection and equipment switching and cutting operations.
Use of environmental conditions
1. Ambient temperature: not higher than 70 ℃, not lower than -40 ℃;
2. Altitude: not more than 2000m;
3. Power frequency: 50/60Hz;
4. Earthquake intensity: 8 degrees and below;
5. Maximum wind speed: 35 m/s.
Product model meaning and its selection

|
Injection mode |
insulating medium |
Hardware |
Arc extinguishing cover |
Product design serial number |
|
single jet
|
porcelain vase
|
hot galvanizing
|
Without arc extinguishing cover |
SSOC1 |
|
With arc extinguishing cover |
SSOC3 |
|||
|
Silicone rubber
|
hot galvanizing
|
Without arc extinguishing cover |
SSOC5 |
|
|
With arc extinguishing cover |
SSOC7 |
Technical parameters
|
Project |
Unit |
Parameter Value |
|
|
Rated operating voltage |
kV |
12 |
|
|
Rated continuous operating current |
A |
100, 200 |
|
|
Rated frequency |
Hz |
50/60 |
|
|
Rated current of fuse base |
A |
100, 200 |
|
|
Rated short-circuit breaking current |
kA |
12.5kA |
|
|
Power frequency withstand voltage (dry test/wet test) |
kV |
60/50 |
|
|
Rated lightning impulse voltage (relative to ground/isolation fracture) |
kV |
125/150 |
|
|
Creepage distance |
porcelain vase |
mm |
372 |
|
|
composite silicone rubber |
|
40 |
|
|
non-load type |
|
2000 (continuous opening and closing) |
|
|
Load type |
|
500 (continuous opening and closing) |
|
Altitude |
m |
2000 |
|
|
Ambient temperature |
℃ |
-40 ~ 70 |
|