35kV drop fuse is widely used in 25kV, 40.5kV high voltage overhead line system, mainly used for distribution transformer short circuit and overload protection, under certain conditions can be broken and closed no-load transformer and small load overhead lines.<br />This product is composed of insulator, melting pipe, terminal and other parts. The insulator is made of silicone rubber material; the melting pipe is made of new material and non-organic pipe wall arc extinguishing material, and the surface of the melting pipe is coated with a special anti-ultraviolet coating to prevent the aging of the melting pipe; the upper and lower contacts are silver-plated on the surface of bronze alloy to ensure the thermal diffusion area, and the conductive part is silver-to-silver contacts. All spring parts of this product are made of stainless steel pressure.<br />This fuse conforms to GB15166.3 and ESB151-095, ANSI C37.42 standard.

SSOC series outdoor drop fuse is mainly used in AC 10kV power system, used for overload and short circuit protection of transmission lines and power transformers, capacitor banks and split rated current, and can also be used as outdoor load switch. Products with reasonable structure, excellent performance, reliable quality for a distribution system to provide a safe and reliable over-current protection.<br />The product conforms to GB15166.3 (AC high voltage fuse, jet fuse) standard.

Products are mainly used in AC 12kV/24kV, 50Hz power system, no-load live high-voltage line switching and isolation, the maintenance of high-voltage bus, circuit breakers and other electrical equipment for electrical isolation, widely used in electric power, railways, mines, oil fields, enterprises and other fields.<br />Products comply with GB1985 "AC voltage isolation switch and grounding switch", GB/T11022 "high voltage switchgear common technical requirements", IEC282.2, IEC787 "high voltage isolation switch" and other standards.

FZW28-12 type vacuum load switch is used for rated voltage 12kV, rated current 630A, three-phase AC 50Hz overhead lines, with manual and automatic operation functions. This switch adopts vacuum arc extinguishing and SF6 gas insulation. It is mainly used for the load current and closing short-circuit current in the power system.<br />The product consists of three parts: switch body, control device and connecting cable.<br />The product conforms to GB3804 "3.6 kV-40.5kV high voltage AC load switch" and GB11022 "common technical requirements of high voltage switchgear and control equipment standard".

< 123 >